|
Olympus
fluoview confocal laser microscope Fluoview Confocal Laser Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/U-LH100HG+Fluorescence+Light+Source/pmc03235125-55-88-93 Average 95 stars, based on 1 article reviews
fluoview confocal laser microscope - by Bioz Stars,
2026-11
95/100 stars
|
Buy from Supplier |
|
Nikon
tie inverted microscope Tie Inverted Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/Objectives/pmc09673094-98-14-18 Average 99 stars, based on 1 article reviews
tie inverted microscope - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Coherent Corp
two photon laser source Two Photon Laser Source, supplied by Coherent Corp, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/Chameleon/pmc11161643-150-16-21 Average 99 stars, based on 1 article reviews
two photon laser source - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Hamamatsu
laser source c6979 Laser Source C6979, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/c6979+power+supply/pm29337193-63-25-28 Average 90 stars, based on 1 article reviews
laser source c6979 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
TOPTICA Photonics
chrome mle laser source Chrome Mle Laser Source, supplied by TOPTICA Photonics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/chrome+mle+laser+source/pmc10848938-422-17-21 Average 90 stars, based on 1 article reviews
chrome mle laser source - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Promega
fluorometer glomax Fluorometer Glomax, supplied by Promega, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/glomax+20+20+luminometer/pm39159713-119-5-7 Average 90 stars, based on 1 article reviews
fluorometer glomax - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Hamamatsu
laser source c7773 Laser Source C7773, supplied by Hamamatsu, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/imaging+spectrograph+hamamatsu+c5094/pm29337193-53-20-23 Average 90 stars, based on 1 article reviews
laser source c7773 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Thorlabs
laser Laser, supplied by Thorlabs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/coupled+fiber+led/pm34381311__cg1c00393_si_001-44-24-25 Average 86 stars, based on 1 article reviews
laser - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
|
Nikon
fluorescent confocal polarising microscopy ![]() Fluorescent Confocal Polarising Microscopy, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/C2%2B/pmc06555807-127-0-6 Average 99 stars, based on 1 article reviews
fluorescent confocal polarising microscopy - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Yokogawa Electric
csu-x1 ![]() Csu X1, supplied by Yokogawa Electric, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/CSU-X1/custom%40csu-x1%4010%2E1091%2Fmbc%2Ee19-04-0224 Average 99 stars, based on 1 article reviews
csu-x1 - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Coherent Corp
laser source ![]() Laser Source, supplied by Coherent Corp, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/Genesis/pm40846863__41377_2025_1941_MOESM1_ESM-264-7-9 Average 96 stars, based on 1 article reviews
laser source - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
IkeCool Corporation
dpss laser source ![]() Dpss Laser Source, supplied by IkeCool Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/laser-source+fluorescence+microscope/dpss+laser/bio_rxiv__2023__06__30__547197-166-12-17 Average 90 stars, based on 1 article reviews
dpss laser source - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: PLoS ONE
Article Title: Cyclical and Patch-Like GDNF Distribution along the Basal Surface of Sertoli Cells in Mouse and Hamster Testes
doi: 10.1371/journal.pone.0028367
Figure Lengend Snippet: Rotating 3D reconstruction showing the close co-localization of a GFRα1-positive spermatogonial cell with immunoreactive GDNF-positive deposits in the basal compartment of seminiferous tubule in hamster testes. PFA-fixed seminiferous tubule fragments were double-stained with anti-GDNF (green) and GFRα1 (red) antibodies (DAPI, blue) without any permeabilization steps, and then analyzed to reconstruct a three-dimensional image using an Olympus FluoView confocal laser microscope (FV10i; Olympus, Japan) in combination with Volocity software (Mitani Sangyo, Japan) (see also
Article Snippet: Without any permeabilization steps using methanol and detergent (Tween20/Triton X-100), the seminiferous tubule fragments were incubated with rabbit anti-GDNF (1∶200 dilution) and goat anti-GFRα1 (1∶100 dilution; R&D Systems)/goat anti-mouse c-kit (1∶100 dilution in mice, 1∶20 in hamsters; R&D Systems) antibodies at 4°C for 12 h. After being washed with PBS, the samples were incubated with Alexa-488/594 conjugated secondary antibodies, including DAPI, at room temperature for 2 h. After counter-staining with DAPI, the samples were analyzed under Olympus fluorescent microscope (BX51N-34-FL2) and stereomicroscope (SZX16 plus U-LH100HG) systems and Olympus FluoView confocal laser microscope (FV10i; Olympus, Japan) in combination with Volocity software (Mitani Sangyo, Japan).
Techniques:
Journal: PLoS ONE
Article Title: Cyclical and Patch-Like GDNF Distribution along the Basal Surface of Sertoli Cells in Mouse and Hamster Testes
doi: 10.1371/journal.pone.0028367
Figure Lengend Snippet: Rotating 3D reconstruction showing the close co-localization of a GFRα1-positive spermatogonial cell with immunoreactive GDNF-positive deposits in the basal compartment of seminiferous tubule in mouse testes. PFA-fixed seminiferous tubule fragments were double-stained with anti-GDNF (green) and GFRα1 (red) antibodies (DAPI, blue) without any permeabilization steps, and then analyzed to reconstruct a three-dimensional image using an Olympus FluoView confocal laser microscope (FV10i; Olympus, Japan) in combination with Volocity software (Mitani Sangyo, Japan) (see also
Article Snippet: Without any permeabilization steps using methanol and detergent (Tween20/Triton X-100), the seminiferous tubule fragments were incubated with rabbit anti-GDNF (1∶200 dilution) and goat anti-GFRα1 (1∶100 dilution; R&D Systems)/goat anti-mouse c-kit (1∶100 dilution in mice, 1∶20 in hamsters; R&D Systems) antibodies at 4°C for 12 h. After being washed with PBS, the samples were incubated with Alexa-488/594 conjugated secondary antibodies, including DAPI, at room temperature for 2 h. After counter-staining with DAPI, the samples were analyzed under Olympus fluorescent microscope (BX51N-34-FL2) and stereomicroscope (SZX16 plus U-LH100HG) systems and Olympus FluoView confocal laser microscope (FV10i; Olympus, Japan) in combination with Volocity software (Mitani Sangyo, Japan).
Techniques:
Journal: Nature Communications
Article Title: Microstructure arrays of DNA using topographic control
doi: 10.1038/s41467-019-10540-2
Figure Lengend Snippet: The in situ contact line changes during the process. Darker images can be observed when the meniscus generates at a φ = 0° and e φ = 45° and enlarged images in the colour boxes show the detailed contact line behaviour b – d φ = 0° and f – h φ = 45°. The red arrow indicates the pulling direction. The drying process follows this direction, producing distinctive contact lines with varying φ . Schematic sketches as the DNA solution dries show how the contact lines were changed at i φ = 0° and j φ = 45°. k , l Fluorescent confocal microscopy images show the cross section view at the α and β regions. The grey blocks indicate microposts. All scales are 10 μm
Article Snippet:
Techniques: In Situ, Confocal Microscopy